Green Energy Eco.com

Recom

Coolcept fleX Hybrid

Single-phase hybrid inverters StecaGrid 2021 | 3021 | 3021_2 | 3621_2 | 4621_2 | 5021_2
  • up to 5 kW power, also in battery mode
  • optional backup power function
  • integrated NA protection
  • up to 2 MPP-tracker
  • integrated WiFi
  • robust IP65 casing
  • easy installation
  • temperature controlled internal fan

(incl. 12 % GST plus shipping)

Product Inquiry

Technical Specification

    StecaGrid Hybrid 2021 StecaGrid Hybrid 3021 StecaGrid Hybrid 3021_2 StecaGrid Hybrid 3621_2 StecaGrid Hybrid 4621_2 StecaGrid Hybrid 5021_2
DC input side (PV generator connection) Maximum input voltage 450 V 750 V 750 V
MPP voltage range 75 V … 360 V 75 V … 600 V 75V … 600 V
Operating voltage range at nominal power (1 MPP) 135 V … 360 V 205 V … 600 V 205 V … 600 V 250 V … 600 V 310 V … 600 V 343 V … 600 V
Operating voltage range at nominal power (2 MPP) 110 V … 600 V 125 V … 600 V 160 V … 600 V 170 V … 600 V
Number of MPP trackers* 1 1 2
Maximum input current 15 A 15 A 2 x 15 A
Max. input power at max. output active power 2050 W 3070 W 3070 W 3770 W 4710 W 5150 W
Max. short circuit current 17 A 17 A 17 A 17 A 17 A 17 A
     
DC input side (battery connection) Maximum input voltage 360 V 600 V 600 V
Voltage range 75 V … 360 V 75 V … 600 V 75 V … 600 V
Operating voltage range at rated power 135 V … 360 V 205 V … 600 V 205 V … 600 V 250 V … 600 V 310 V … 600 V 343 V … 600 V
Maximum input current 15 A 15 A 15 A
Max. input power at max. output active power 2050 W 3070 W 3070 W 3770 W 4710 W 5150 W
     
 

AC output side (mains connection)

Output voltage 185 V … 276 V
Rated output voltage 230 V
Maximum output current 12 A 14 A 14 A 16 A 20 A 22 A
Maximum active power (cos phi = 1) 2000 W 3000 W 3000 W 3680 W 4600 W 5000 W
Maximum apparent power 2000 VA 3000 VA 3000 VA 3680 VA 4600 VA 5000 VA
Rated power 2000 W 3000 W 3000 W 3680 W 4600 W 5000 W
Rated frequency 50 and 60 Hz
Mains frequency 45 … 60 Hz
Power loss during night operation < 3 W
Feed-in phase single-phase
Distortion factor (cos phi = 1) < 3 %
Power factor cos phi 0.8 capacitive…. 0.8 inductive
Highest output fault current 0.0 A
Highest output overcurrent protection 28 A 40 A 57 A 57 A 57 A 57 A
     
Characterization of the operating behaviour Maximum efficiency 97.40 % 97.00 % 97.00 % 97.00 % 97.40 % 97.40 %
European efficiency 96.50 % 96.30 % 96.30 % 96.30 % 96.90 % 96.80 %
MPP Efficiency > 99.7 % (static), > 99 % (dynamic)
Self-consumption < 20 W
     
 

Safety

Separation principle no galvanic isolation, transformerless
Mains monitoring yes, integrated
Residual current monitoring Yes, integrated (the inverter cannot cause a DC fault current due to its design).
Protection class Protection class 2 (RCD type A sufficient)
     
 

Operating conditions

Application area indoor / outdoor
Climatic class according to IEC 60721-3-4 4K4H
Ambient temperature -25 °C … +60 °C
Storage temperature -30 °C … +80°C
Relative humidity 0 % … 100 % non-condensing
Noise emission (typical) 31dBA
     
 

Equipment and design

Protection class IP65
Overvoltage category III (AC), II (DC)
DC connection 1 pair 1 pair Phoenix Contact SUNCLIX (2 pair), mating connector included in scope of delivery
AC connection connector Wieland RST25i3, mating connector included in scope of delivery
Dimension (X x Y x Z) 399 x 657 x 222 mm
Weight 12.6 kg 13.8 kg 14 kg
 

Communication interface

RS485 (1x RJ45: connection to optional energy manager / data logger); RS485 Modbus (1x RJ45: con- nection to energy meter, 1x RJ45: connection to battery system); Ethernet interface (1x RJ45), integrated WiFi
Integrated DC load break switch yes, compliant with DIN VDE 0100-712
Cooling principle temperature controlled fan, variable speed, internal (dust protected)
Test certificates see certificate download on the product page of the Steca website
Select your currency
EUR Euro